What is ERR3?

ERR3is displayedwhen the batch tank fill volume is significantly greater than expected.

Most Common Cause: leak in the nozzle circuit.

Other Potential Causes:

  • System Setup does not reflect installed system – 1) more nozzles installed than entered, 2) actual flow rate (AFR)is much greater than estimated nozzle flow rate (NFR) in controller, 3) the tolerance in the error calculation (TOL) is too small
  • Flowmeter: 1) not working properly, 2) flow of water from the faucet is too high or turbulent for flowmetertoread correctly.

TroubleshootingSteps:

1. Attempt to reproduce ERR3:
  • Clear error – press Red MENU/Stop button for 5 seconds.
  • Run Manual Mist – press the Up and Down arrow simultaneously and hold for 2 secs.
  • If ERR3 results, proceed with next steps. Otherwise, run more Manual Mists to ensure system is workingproperly. (see Note about Slow/Small Leaks in Step 5)
2. Confirm System Setup is correct:
  • Confirm nozzle count in controller (NOZ in Setup Menu) reflects number of nozzles installed.
  • Confirm nozzle flow rate (NFR in DATA Menu) is reasonable (35 – 50 ml/min)
  • Confirm tolerance (TOL in DATA Menu) is correct:
Nozzle CountTolerance (TOL)
less than 3075%
30 to 5050%
greater than 5025%
  • If Setup changes are required, run Manual Mists to confirm system is working properly.

3. Confirmflowmeter is working correctly with Flowmeter Diagnostic.

4. Inspect nozzle circuit for leaks.

  • Run an extended inspection cycle (MTCE Menu, press and hold INS) and look for leaks

5. Note About Slow, “Line-Fill” Leaks:

During the hours between mist cycles, fluid can leak out of a fitting or drip out of nozzles and drain the nozzle circuit. The next time the unit mists, the nozzle circuit must be refilled completely and this may be a large enough additional volume to cause an ERR3. Small leaks are notoriously difficult to troubleshoot because they are difficult to reproduce while onsite.

6. Additional Resources for Troubleshooting ERR3:

Gen 3: Troubleshooting ERR3 - MistAway Pro (2024)
Top Articles
Latest Posts
Article information

Author: Rubie Ullrich

Last Updated:

Views: 6300

Rating: 4.1 / 5 (72 voted)

Reviews: 95% of readers found this page helpful

Author information

Name: Rubie Ullrich

Birthday: 1998-02-02

Address: 743 Stoltenberg Center, Genovevaville, NJ 59925-3119

Phone: +2202978377583

Job: Administration Engineer

Hobby: Surfing, Sailing, Listening to music, Web surfing, Kitesurfing, Geocaching, Backpacking

Introduction: My name is Rubie Ullrich, I am a enthusiastic, perfect, tender, vivacious, talented, famous, delightful person who loves writing and wants to share my knowledge and understanding with you.